Category | Basic | Standard | Premium | Dynamic | |||
Type | RM 2106 | RM 2112 | RM 9606 | EMR 1100S | EMR 1100 | RM 2012 6+6D | RM 2012 12D |
Article-No. | 38-00320 | 38-00340 | 38-00100 | 38-00300 | 20-50006 | 39-29050 | 39-29051 |
Article-No. | 38-00320 | 38-00340 | 38-00103 | 38-00301 | 20-50008 | 39-29050 | 39-29051 |
Voltage | L-N | L-N | L-N / L-L | L-N / L-L | L-N / L-L | L-L | L-L |
Operating / Measurement voltage [V] | 220 - 240 | 220 - 240 | 220 - 400 | - | - | 400 | 400 |
Operating | - | - | - | 220 - 240 | 220 - 240 | - | - |
Measurement | - | - | - | 100 - 690 | 100 - 690 | - | - |
Power | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 | 50 / 60 |
Current measurement | single phase | single phase | single phase | single phase | single phase | single phase | single phase |
Operating current min. [mA] man. programming | 20 | 20 | 20 | 20 | 20 | 10 | 10 |
Operating current min. [mA] automatic detection | 20 | 20 | 20 | 20 | 20 | 50 | 50 |
Current transformer X/…A | 1 -5 | 1 -5 | 1 -5 | 1 -5 | 1 -5 | 1 -5 | 1 -5 |
Contact termination | man/auto | man/auto | man/auto | man/auto | man/auto | man/auto | man/auto |
Soll-cos phi | 0,85 ind. - 1 | 0,85 ind. - 1 | 0,80 ind. - | 0,80 ind. - | 0,80 ind. - | 0,80 ind. - | 0,80 ind. - |
Control characteristic - settings | fixed | fixed | variable | variable | variable | fixed | fixed |
Control characteristic - number | 1 | 1 | 1 | 1 | 2 | 2 | 2 |
Switching sequence | man/auto | man/auto | man/auto | man/auto | man/auto | man/auto | man/auto |
Number of aktive switching outputs | man/auto | man/auto | man/auto | man/auto | man/auto | man/auto | man/auto |
Programmable | 0 | 0 | 3 | 3 | 3 | 3 | 3 |
Relais-switch contacts | 6 | 12 | 6 | 12 | 12 | 6 | 0 |
Power rating | 230 V / 950 VA | 230 V / 950 VA | 250 V / | 250 V / | 250 V / | 250 V / | - |
Consumer net with regulation on inductive set cos phi | RM 2106 / RM 2112 / |
Consumer- and electricity producer net with regulation in all 4 quadrants | RM 9606 / EMR 1100S / EMR 1100 |
Measurement value logging of voltage and current (medium voltage) | EMR 1100S / EMR 1100 |
Choked Power Factor Correction Systems with detuning factors <7% or networks with sporadically higher harmonic | EMR 1100S / EMR 1100 |
Dynamic Reactive Power Control Systems | RM 2012 12D |
Teildynamische Reactive Power Control Systems | RM 2012 6+6D |
【德國(guó)原裝進(jìn)口】FRAKO
FRAKO電容器 FRAKO濾波器 FRAKO控制器 FRAKO補(bǔ)償器 FRAKO電抗器 FRAKO電解電容
RM2106 RM2112 RM9606 EMR1100S EMR1100 [RM2012 6+6D] [RM2012 12D]
Power Factor Control Relays
Beneficial features
The connected Reactive Power Control System and the net to be compensated is automatically detected by the intelligent. FRAKO Power Factor Control Relays. Thereby incorrect programming
is automatically avoided. Incorrect connections or inaccurate positioning of the transformers will be identified and indicated.
Time- and cost-consuming error diagnostics can be avoided by this. The selected set cos phi is regulated by the patented control characteristics as a minimum value at normal load and also avoids an over-compensation at peak-off load. Thereby reactive power costs can certainly be avoided and the risk of main disruptions can be reduced.
The intelligent operation method ensures that the target value will be regulated and hold with a minimum of possible switchings. This minimizes the wear of the Power Factor Correction System and reduces retroactive effects at the net. Depending on the version the Power Factor Control Relays protect the Power Factor Correction System from a too high harmonic content by switching of the system.
Additionally our clients appreciate the user-friendly operation of our Power Factor Control Relays.